EVALUASI KEYAMANAN TERMAL DENGAN MODEL STATIS PADA KANTIN KAMPUS UNIVERSITAS ICHSAN GORONTALO

Authors

  • Amru Siola Universitas Ichsan Gorontalo
  • Bambang Apriyanto Universitas Ichsan Gorontalo

DOI:

https://doi.org/10.37971/radial.v9i2.252

Keywords:

Evaluasi, Kenyamanan Termal, Model Statis, Ruang Semi Outdoor, Kantin Kampus

Abstract

Abstrak: Evaluasi Keyamanan Termal Dengan Model Statis Pada Kantin Kampus Universitas Ichsan Gorontalo. Bangunan berfungsi sebagai penyedia ruang untuk menunjang aktivitas manusia. Aktivitas manusia dapat terlaksana secara baik melalui pemenuhan ruang yang nyaman. Kenyamanan didefinisikan sebagai suatu kondisi tertentu yang dapat memberikan sensasi yang menyenangkan, khususnya bagi pengguna bangunan. Saat ini, eksistensi kantin atau cafe di Gorontalo semakin berkembang dan tumbuh pesat di Kota Gorontalo, seperti kedai, warung, coffee shop, dan cafe. Desainnya yang direfleksikan juga beragam seperti desain ruang dalam, ruang luar, dan ruang semi outdoor yang berfungsi sebagai tempat berkumpul sehingga kenyamanan termal pada kantin sangatlah penting. Kombinasi secara tepat beberapa variabel dapat menciptakan kenyamanan termal di dalam bangunan. Fokus  penelitian  adalah  kenyamanan termal kantin kampus Universitas Ichsan Gorontalo. Metode yang  digunakan  pada  penelitian  ini  adalah  observasi  lapangan  yang memanfaatkan  alat  pengukur temperatur dalam dan luar ruangan, pergerakan udara, kelembaban, dan temperatur lingkungan. Hasil pengukuran dijabarkan dalam bentuk grafik dan dijelaskan secara deskriptif kuantitatif. Karakteristik lingkungan termal menunjukkan bahwa suhu udara pada jam 09.00 masih dalam tahap normal, namun ada peningkatan pada jam 10.00 (jam istirahat sesi pertama).  Hasil penelitian menunjukkan bahwa karakteristik lingkungan termal berada pada suhu minimum 30,9°C dan suhu maksimumnya 32,3°C.  Hal itu mengindikasikan bahwa suhu udara telah melewati ambang batas nyaman, yaitu 31°C.

Kata Kunci: Evaluasi, Kenyamanan Termal, Model Statis, Ruang Semi Outdoor, Kantin Kampus.

Abstract: Evaluation Of Thermal Comfort Using Static Model At Campus Canteen Of Universitas Ichsan Gorontalo. A building functions as a space provider to support human activities.  The fulfillment of a comfortable space helps humans in carrying out activities properly. Comfort means a specific condition that can provide a pleasant sensation, especially for building users. Currently, the existence of a canteen or cafe in Gorontalo has been increasing rapidly in Gorontalo City, such as shops, stalls, coffee shops, and cafes. They reflect in a variety of designs, such as indoor spaces, outdoor spaces, and semi-outdoor spaces that function as gathering places so that thermal comfort in a canteen is very significant. The right combination of several variables can create thermal comfort in the building. The research focus is the thermal comfort at the campus canteen of Universitas Ichsan Gorontalo. The research method applies field observation using indoor and outdoor temperature measuring instruments, air movement, humidity, and ambient temperature. The measurement results are described in graphs and elaborated in a quantitative descriptive method. The characteristics of the thermal environment show that the air temperature at 09.00 is categorized as at the normal stage, but there is an increase at 10.00 (first session break). The results show that the characteristics of the thermal environment were at a minimum temperature of 30.9°C and a maximum temperature of 32.3°C. This indicates that the air temperature has passed the comfortable threshold, which is 31°C.

Keywords: Evaluation, Thermal Comfort, Static Model, Semi Outdoor Room, Campus Canteen.

Downloads

Published

2022-02-11

Issue

Section

Articles